I. Overview
DZ15LE series leakage circuit breaker (hereinafter referred to as circuit breakers (air switch) it is a neutral-to-ground leakage protection device is suitable for AC 50Hz or 0Hz, rated voltage of 380V, rated current up to 63A (100A) circuit, not frequently used for leakage protection, but also can be used to prevent the risk of fire caused damage of equipment insulation, ground fault current, and can be used to protect the circuit and motor overload and short circuit, and can also be used as line not frequent conversion and motor starting with. leakage circuit breakers rated residual operating value can toggle circuit breaker according to the actual requirements of the rated residual operating value based on actual usage requirements toggle adjustment.
This product meets the GB6829-95, GB14048.2-94 standard.
Second, the model and their meanings

Ministry strike vibration and rain and snow on the wiring terminals connected to the supply side, under wiring and terminal load side, and the vertical gradient of not more than 50 ° C.
Third, the use of environmental conditions
Installation site altitude does not exceed 2000m
The ambient air temperature
1) maximum ambient air temperature does not exceed +40 ° C:
2) the average ambient air temperature within 24h does not exceed +35 ° C;
3) air temperature around the lower limit value of not lower than -50 ° C;
Category: divided into: two, three, four, three four-wire circuit breaker series.
Divided disconnect use: power distribution, motor protection (for three).
Atmospheric conditions
More than 50% of the relative temperature of the atmosphere around the highest temperature is +40 ℃, higher relative humidity at lower temperatures, the wettest month average minimum temperature does not exceed +25 ℃, the monthly mean maximum relative temperature was 90%, and taking into account the condensing temperature changes occur in the surface of the product.
Installation Category Ⅲ class
Pollution degree 3
Third, the leakage breaker An Peiyu places near the outer magnetic field in any direction should not exceed the earth's magnetic field of 5 times.

  
DZ15LE series leakage circuit breaker (hereinafter referred to as breaker (air switch), it is a kind of neutral to earth leakage protective device, applied to ac 50 hz or 0 hz and rated voltage of 380 v, rated current 63 a, 100 a) of the circuit, and used as electrical leakage protection, can also be used to prevent due to the damage of equipment insulation, fire danger caused by the grounding fault current, and can be used to protect circuits and motor overload and short circuit, a line not frequent transformation and also the don't frequent starting of the motor. The leakage circuit breaker leakage rating action value according to actual use requirement can strike rated leakage circuit breaker action value according to the practical application requirements can be adjusted upon.